Skip to main content

Guide

India's grid emission factor: which number to use for Scope 2

The Central Electricity Authority publishes India's grid emission factors once a year. The latest values, what each one means, and how to use them.Updated 13 November 2026

The latest values

Weighted average · FY 2025-26

0.675tCO₂ per MWh

Every grid-connected station, weighted by generation. The usual factor for a location-based Scope 2 figure.

  • Operating margin

    0.963

    Stations other than low-cost and must-run sources.

  • Build margin

    0.446

    The newest 20% of generation added to the grid.

  • Combined margin

    0.705

    The operating and build margins, weighted 50:50.

Data · CEA, CO₂ Baseline Database for the Indian Power Sector, Version 22.0 (August 2026). All-India grid, FY 2025-26, adjusted for cross-border transfers, including renewable and captive generation.

Five years of the weighted average

Weighted average emission factor, tCO₂/MWh

Weighted average emission factor, tCO₂/MWh, by year
2021-222022-232023-242024-252025-26
0.7120.7160.7270.7100.675
Data · CEA, CO₂ Baseline Database, Version 22.0. Weighted average, adjusted for cross-border transfers, including renewable generation.

CEA puts the fall since FY 2023-24 down to the growing share of non-fossil generation.

CEA revises earlier years when better data arrives: Version 22.0 revised FY 2024-25. Quote the version as well as the year.

Which factor for what

The four factors CEA publishes, what each averages, and what each is used for
FactorWhat it averagesUsed for
Weighted averageAll grid-connected stations, weighted by generationLocation-based Scope 2 figures
Operating marginStations other than low-cost and must-run sourcesBaselines for carbon-credit projects
Build marginThe newest 20% of generation added to the gridBaselines for carbon-credit projects
Combined marginThe operating and build margins, weightedBaselines for grid-connected renewable projects

Working out a Scope 2 figure

120 MWh

Electricity used in the year (120,000 kWh)

0.675

tCO₂ per MWh, CEA weighted average, FY 2025-26

81 tCO₂

Location-based Scope 2

120 MWh Electricity used in the year (120,000 kWh) times 0.675 tCO₂ per MWh, CEA weighted average, FY 2025-26 equals 81 tCO₂ Location-based Scope 2

Example · a site that used 120,000 kWh in FY 2025-26. The figures are illustrative.
  • Divide the kWh on your bills by 1,000 to get MWh.
  • Add up every meter inside your boundary, for every month.
  • Use the factor for the same year as your electricity data, where CEA has published it, and name the version.
  • CEA's factors cover CO₂ only. Say so beside the figure.
  • A market-based figure, if you report one, uses your supplier's or contract's factor instead.

Where to find it

CEA publishes the database once a year, after the fiscal year closes: a user guide and an Excel file covering every grid-connected station. The user guide is linked in the sources below.

Carbon Intelligence & Accounting

Sources