Skip to main content

Guide

How to prepare for a GHG verification

What a verifier will ask for, in the order they ask for it, and a checklist to work through first.Updated 13 November 2026

How a verification runs

  1. Agree the terms

    Boundary, period, criteria, scopes, level of assurance and materiality, in writing.

  2. Plan and test

    The verifier finds where errors are most likely, then gathers evidence there.

  3. Conclude

    Findings are raised and resolved; the statement covers the final figures.

Diagram · the three stages of an ISO 14064-3 verification, simplified.

What to settle first

You decide

  • Which sites and entities are in, and the consolidation approach behind it
  • The reporting period
  • The criteria: GHG Protocol or ISO 14064-1
  • The scopes, and which Scope 3 categories

You agree with the verifier

  • Limited or reasonable assurance
  • The materiality threshold
  • Which sites are visited, and when
  • Who answers the verifier's questions
Diagram · the decisions to make before the verification starts.

The evidence pack

Gather these before the verifier asks. Each one is something a reported figure should lead back to.

GHG verification evidence checklist

Across the inventory

  • A written note of the boundary and the consolidation approach
  • The calculation workbook, with its formulas intact
  • Every emission factor, with its source and year
  • Assumptions and estimates, each with its reason
  • What changed since last year, and why
  • The base year, and the rule for recalculating it

Scope 1

  • Fuel invoices or purchase records, for each fuel
  • Meter readings or logs for boilers, furnaces and generators
  • Vehicle fuel cards or logbooks
  • Refrigerant top-up and service records
  • Production data behind any process emissions

Scope 2

  • Electricity bills for every meter in the boundary, for every month
  • Bills for steam, heat or cooling bought in
  • The grid emission factor used, with its database version and year
  • Contracts or certificates, if you also report a market-based figure

Scope 3, if included

  • A screening of all 15 categories, with why each is in or out
  • Supplier data, where you have it
  • Spend or quantity data, with the factors applied
  • A note of which figures are estimates
Checklist · from the GHG Protocol's and ISO 14064-1's reporting requirements, and what an ISO 14064-3 verifier tests.

What the verifier does with it

  • Recalculates a sample

    Takes your activity data and factors and works the numbers again.

  • Traces figures to records

    Follows reported figures back to bills, logs and readings.

  • Checks nothing is missing

    Compares the boundary with the sites, meters and sources that exist.

Diagram · the core tests, at either level of assurance. Reasonable assurance applies them more widely.

Findings are normal. The verifier raises them, you correct or explain, and the statement covers the corrected figures.

Gaps that hold a verification up

  • Months of bills missing for one meter or site
  • Emission factors with no source or year
  • A site that's in the accounts but not in the inventory
  • Numbers typed over formulas in the workbook
  • No one named to answer the verifier's questions

How verification works at Mynkle

Sources

  • ISO 14064-3:2019, Greenhouse gases, Part 3: specification for the verification and validation of greenhouse gas statements. ISO.
  • ISO 14064-1:2018, Greenhouse gases, Part 1: specification for quantification and reporting at the organization level. ISO.
  • GHG Protocol Corporate Accounting and Reporting Standard, revised edition. World Resources Institute (WRI) and World Business Council for Sustainable Development (WBCSD).
  • GHG Protocol Scope 2 Guidance. WRI and WBCSD.
  • GHG Protocol Corporate Value Chain (Scope 3) Accounting and Reporting Standard. WRI and WBCSD.